Complete system overview

Engineered comfort from the outside in

Explore the construction, installation flexibility, controls, electrical heat options, and dimensions behind the VANDOSS matched HVAC system.

VANDOSS heat pump VANDOSS air handler VANDOSS A-coil

Built for dependable performance

Product features

Durable louvered steel coil guard supports long-lasting outdoor performance.

Heavy-duty steel wire grille protects the top-discharge axial fan.

Sweat-type suction and liquid service valves include gauge ports for easier diagnostics.

Thermal overload protection works with a factory-standard high-pressure switch.

Foil-faced insulation reduces energy loss and helps control condensation.

A dedicated control-board enclosure shields electronics from humid airstreams.

Painted galvanized steel cabinetry is salt-spray tested for durability and corrosion resistance.

A corrosion-resistant composite base pan is sloped to reduce standing water.

Optional electric heat can be added without cabinet modification.

A two-stage ECM indoor blower supports comfort, efficiency, and humidity control.

Flexible by design

Installation, airflow, and controls

Multi-position installation

Horizontal or vertical installation supports upflow, downflow, and horizontal left or right configurations.

High-volume airflow

A constant-torque ECM fan delivers strong external static pressure so conditioned air reaches every room.

24V or Wi-Fi control

Choose a standard 24V thermostat, wired controller with Wi-Fi, or optional leakage-detector sensor kit.

Optional comfort support

Electrical heater data

ModelkW 208/230Heater kit FLA (A)Min. circuit amps (A)Max. breaker (A)
EH-K05E3.8 / 518.2 / 20.825 / 2625 / 30
EH-K08E5.6 / 7.527.9 / 31.935 / 4035 / 40
EH-K10E7.5 / 1036.3 / 41.746 / 5550 / 60
EH-K15E5.6+5.6 / 7.5+7.527.9+27.9 / 31.9+31.935+35 / 40+4035+35 / 40+40
EH-K20E7.5+7.5 / 10+1036.3+36.3 / 41.7+41.746+46 / 55+5550+50 / 60+60

Electrical heater kits are optional. Final selection must follow the applicable model documentation and local electrical requirements.

System dimensions

Dimensions and connections

Bottom air return AHU

CapacityUnitWDHLiquidGas
18K / 24KOutdoor23-5/823-5/8253/83/4
30K / 36KOutdoor29-9/6429-9/64253/83/4
42K / 48K / 60KOutdoor29-9/6429-9/6432-7/83/83/4
18K / 24KIndoor17-33/6421-1/32423/83/4
30K / 36KIndoor21-1/3221-1/3249-1/643/83/4
42K / 48K / 60KIndoor24-31/6421-1/3252-63/643/83/4

Front air return AHU

CapacityUnitWDHLiquidGas
18K / 24KOutdoor23-5/823-5/8253/83/4
30K / 36KOutdoor29-9/6429-9/64253/83/4
18K / 24KIndoor20-15/3214-61/6436-1/323/83/4
30K / 36KIndoor22-3/6419-3/3239-9/163/83/4